Huadian Technology ›› 2018, Vol. 40 ›› Issue (1): 10-12.

Previous Articles     Next Articles

Calculation of ice thickness of overhead transmission lines

  

  1. Hunan Electric Power Construction Supervision & Consultancy Corporation Limited, Changsha 410002,China
  • Online:2018-01-25 Published:2018-02-07

Abstract:

Through establishing icing thickness mechanical models for overhead transmission lines, the formula for calculating the ice thickness of lines and wire sag is derived. Using the formula, thickness of the ice coating of ±800kV Fufeng line in Hunan region was calculated. Comparing the calculating results with field test results, the calculation error was 9.02%. The model can be used to predict the thickness of wire ice coating in advance, and provides a preliminary warning for icing protection.