Huadian Technology ›› 2018, Vol. 40 ›› Issue (10): 37-39.

Previous Articles     Next Articles

 
Transformation and thermal economy analysis on 1000MW ultra supercritical unit with lowtemperature fuel economizer

  

  1.  
    Huadian Laizhou Power Generation Company Limited, Yantai 261441, China
  • Online:2018-11-26 Published:2018-12-13

Abstract:

 

Taking the 1000MW ultrasupercritical boiler of #1 unit in Laizhou Power Generation Company whose annual average smoke temperature reaches 126℃, management integrating flue and gas emission regulation, as well as lowtemperature economizer at outlet of air preheater are adopted to reduce the boiler exhaust temperature and absorb the boiler heat loss. It expounds the layout and water intake scheme of the lowtemperature economizer of 1000MW ultrasupercritical unit, and analyzes the thermal economy of the lowtemperature economizer by equivalent enthalpy drop method. The results demonstrate that the thermal efficiency of the unit is improved by the lowtemperature economizer. It is of feasible and practical reference value in recovery of exhaust heat.

Key words: