Huadian Technology ›› 2018, Vol. 40 ›› Issue (11): 17-20.

Previous Articles     Next Articles

Modification of high temperature reheater and its problem solving

  

  1. Huaneng Chaohu Power Generation Company Limited,Hefei 238015, China
  • Online:2018-11-25 Published:2018-12-29

Abstract:

A 600MW supercritical coalfired generator set in a power plant had stopped  many times because of the weld desoldering of inverted Ubend and weld failure of dissimilar steel of hightemperature reheater since the commissioning. In this case, the power plant carried out the inverted Ubend transformation and displacement modification on dissimilar steel welding joints, according to the requirements of the factory. There has been no tube burst caused by inverted Ubend pipe cracking or dissimilar steel welding joints in the 3 years after the modification.The weld cracks of the small header pipe socket of the reheater appeared after transformation, can be solved by patching and repairing welding.

Key words: