Huadian Technology ›› 2018, Vol. 40 ›› Issue (11): 48-51.

Previous Articles     Next Articles

Test and research of the low voltage ridethrough influence on the converter of coal feeder

  

  1. 1.Control Technology Laboratory,Zhejiang Energy Group Research Institute, Hangzhou 310000, China; 2. Zhejiang Energy Lanxi Power Generation Company Limited, Lanxi 321100, China
  • Online:2018-11-25 Published:2018-12-29

Abstract:

In order to avoid the power plant tripping due to low voltage disturbance of the power plant which triggers the protection action of the unit, the test of the influence of low voltage on the converter of the coal feeder was carried out according to the specific conditions of the equipment of Zhejiang Energy Lanxi Power Generation Company Limited. It proposed a method of low voltage ridethrough for coal feeder frequency converter of directfiring pulverizing system with middle speed mill.

Key words: