Huadian Technology ›› 2018, Vol. 40 ›› Issue (12): 56-57.

Previous Articles     Next Articles

Brief analysis of reducing method for TOC mass concentration in boiler makeup water

  

  1. Huadian Qingdao Power Generation Company Limited, Qingdao 266031, China
  • Published:2018-12-25

Abstract:

The mass concentration of TOC in boiler makeup water has been exceeding the standard due to the large amount of water supply during heating. The cation conductivity of makeup water and steam are way below the standard. Analyzing the TOC source of boiler makeup water and the TOC removal ability of water treatment equipment, a solution is proposed to solve the problem of unqualified boiler makeup water and steam.

Key words: