Huadian Technology ›› 2018, Vol. 40 ›› Issue (5): 13-16.

Previous Articles     Next Articles

ACC design optimization for gas turbine combined cycle units

  

  1. Shanghai Electric Power Generation Engineering Corporation, Shanghai 201612, China
  • Published:2018-07-25

Abstract:

According to the basic principles of heat transferring,it creates a mathematical model of heat transferring area and power consumption of ACC affected by initial temperature difference (ITD) and head wind velocity. Taking an Fclass oneplusone CCPP as an example, it calculates the influence of ITD and head wind velocity on net output and ACC heat transferring area of power plant and obtains the optimized ACC design parameters.

Key words: