Huadian Technology ›› 2018, Vol. 40 ›› Issue (9): 66-69.

Previous Articles     Next Articles

Analysis on the influencing factors of thermal power consumption of power generation for S109FA combined cycle units

  

  1. Guangzhou Development Power Group Company Limited, Guangzhou 510627, China
  • Online:2018-09-25 Published:2018-10-12

Abstract:

:Based on the actual operation conditions of two 390MW S109FA gassteam combined cycle generating units of a power plant in Guangzhou,it analyses the major influencing factors of thermal power consumption rate of power generation. According to the query function of historical data in PI database, quantitative analysis can be made on the influence of these factors through practical cases. The quantitative analysis result proves the availability of the analysis method above. At the same time,the result of  analytic procedure provides calculating basis for the quantitative analysis on the features of variable working condition of the units.