Huadian Technology ›› 2019, Vol. 41 ›› Issue (1): 27-31.

Previous Articles     Next Articles

Flow field optimization and energy saving based on antinoise fan pipes

  

  1. 1.Shenhua Guoneng Hami Coal Power Company Limited,Hami 839000, China; 2.Nanjing Changrong Acoustic Incorporated,Nanjing 210000, China
  • Online:2019-01-25 Published:2019-02-14

Abstract:

The vertical blast pipe has certain flow field design defect which results in the increase of draft loss. However, the muffler installed to reduce the noise accelerates the power consumption of fan. Improved design of fan pipes combines antinoise and flow field optimization, which makes pipe itself has a certain muffling performance. The energy saving of fan is achieved by improving the flow field of the pipe and reducing the draft loss. Numerical analysis and demonstration project application show that after the antinoise and flow field optimization of the fan pipe, the muffling energysaving pipe can achieve the muffling effect as ordinary mufflers,and increase the efficiency of the fan by more than 10%. This pipe has the advantages of simple structure,good environmental adaptability,low maintenance cost,excellent application and promotion prospects.

Key words: