Huadian Technology ›› 2019, Vol. 41 ›› Issue (2): 52-54.

Previous Articles     Next Articles

Reasons and regulation measures of low reheat steam temperature under variable load

  

  1. Yantai Longyuan Electric Power Technology Company Limited, Beijing 100039, China
  • Online:2019-02-25 Published:2019-03-13

Abstract:

Reheat steam temperature has great influence on power generation efficiency.Regulation measures of the reheat steam temperature after low NOx combustion modification has been worthy of further study for the electric power workers. In low load conditions, the characteristics of the unit and the control ofreheat steam temperature change significantly with variable load. As the reheat steam temperature under the variable load is generally low after the low NOx combustion modification of the boiler, the cause analysis is carried out, and the countermeasures for the reheat steam temperature regulation are put forward.The adjustment strategy was implemented on the 330MW boiler, which reduced the fluctuation of the reheat steam temperature under variable load, and provided experience for the stability of the reheat steam temperature.

Key words: