Abstract:

There were several tube bursts in the highpressure superheater of NG-M701F-R heat recovery boiler during its initial operation,which seriously affected the safety of the unit.Cause analysis is conducted from operation modedesuperheating waterweldingstructure and  exhaust gas of the unit.It is convinced that periodic thermal stressoverrange desuperheating water flowpoor welding qualityunreasonable structure of tube bundles and rotating exhaust gas flow are the main reasons. By optimizing operation mode of the unitstrengthening management of highpressure superheater maintenanceadding compensation bendreinforcing the antivibration bracket and installing antivibration beam, tube in the highpressure can be protected from burst.

Key words:

font-size: 10.5pt, mso-spacerun: 'yes', mso-font-kerning: 1.0000pt">NG-M701F-R, heat recovery boiler, highfont-size: 10.5pt, mso-spacerun: 'yes', mso-font-kerning: 1.0000pt">font-size: 10.5pt, mso-spacerun: 'yes', mso-font-kerning: 1.0000pt">pressure superheater, tube burst, desuperheating water flow, welding quality, structure of tube bundles, rotating exhaust gas flow