Huadian Technology ›› 2019, Vol. 41 ›› Issue (7): 70-72.

Previous Articles     Next Articles

Reasons analysis for tube blasting and preventive measures for superheater of 1000MW supercritical boiler

  

  1. Huadian Laizhou Power Generation Company Limited,Yantai 261441, China

  • Online:2019-07-25 Published:2019-08-08

Abstract:

For a 1000MW ultrasupercritical boiler after ignition and gridconnected to full load in a plant,  there was a leakage accident due to the blasting pipe in high temperature superheater. Through metallographic examination, cause analysis and orifice inspectation, the reason for the tube burst in high temperature superheater is determined and relevant countermeasure is made, which has certain reference and guiding significance for the same type supercritical boiler in preventing tube bust and safe operation.

Key words:

font-size: 10.5pt, mso-spacerun: 'yes', mso-font-kerning: 1.0000pt">ultra supercritical, high temperature superheater, metallographic examination, overheating tube blasting, preventive measuresfont-size: 10.5pt, mso-spacerun: 'yes', mso-font-kerning: 1.0000pt">