Optimization research on deflectors installed in rightangle bend tube with rectangular section

  

  1. 1.Electric Power Research Institute,Yunnan Power Grid Company Limited,Kunming 650217, China; 2.School of Control and Computer Engineering, North China Electric Power University,Beijing 102206, China

  • Online:2019-08-26 Published:2019-09-06

Abstract:

In order to improve the flow field uniformity in a rightangle bent tube with rectangular section, the fluid flow in the elbow was numerically simulated by FLUENT software. The effects of the uniformity of flow field and local resistance and energy loss in the elbow were analyzed by using different quantities and structures of flow deflectors. The results show that the velocity distribution is not uniform,  vortex and secondary flow occurs when the flow deflectors are not installed in the elbow, while the uniformity of flow field can be effectively improved after arranging the deflector plates; using a reasonable number of baffles can not only effectively improve the flow field uniformity and completely eliminate the vortex and secondary flow caused by the rightangle elbow, but also greatly reduce the flow resistance and energy loss. Through the numerical simulation analysis of the deflectors of three different design schemes, the optimal number and structure of the deflectors are obtained.

Key words:

font-size: 10.5pt, mso-spacerun: 'yes', mso-font-kerning: 1.0000pt">rightfont-size: 10.5pt, mso-spacerun: 'yes', mso-font-kerning: 1.0000pt">font-size: 10.5pt, mso-spacerun: 'yes', mso-font-kerning: 1.0000pt">angle bent tube, flow field uniformity, deflectors, numerical simulation