Huadian Technology ›› 2008, Vol. 30 ›› Issue (11): 49-50.
• 一线动态 • Previous Articles Next Articles
WANG Yuhe,PEI Gongjie
Received:
Revised:
Published:
Abstract: The abnormal current of main motor occurred in air preheater operation was analyzed deeply, the scheme for solving this problem was proposed, and relevant measures were adopted. After the improvement, the air preheater operated safely, and the reliability and economic efficiency of equipment were raised greatly.
Key words: air preheater, main motor, auxiliary motor, frequency converter, improvement of external gear oil pump
WANG Yuhe;PEI Gongjie. The improvement measures for air preheater optimization in 300MW unit[J]. Huadian Technology, 2008, 30(11): 49-50.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2008/V30/I11/49
Optimization of air preheater leakage control system in 670MW unit
Study on the distribution and optimization control of SCR denitration system flue gas flow field
Operation optimization an SCR denitration system in a coalfired power plant