Huadian Technology ›› 2013, Vol. 35 ›› Issue (11): 82-83.
Previous Articles Next Articles
Published:
Abstract: Abstract:The treatment process of inferior sealing of the 350MW unit vacuum system of a power plant was introduced. The conventional treatment mode of vacuum system sealing was analyzed. The result in this paper provides reference for other units to treat similar problems.
Key words: Key words:350MW unit, vacuum system, shaft seal of lowpressure cylinder, sealing, leakage point
WU Henggang, WANG Zhongao. Analysis of case and treatment of inferior sealing of vacuum system of 350MW unit[J]. Huadian Technology, 2013, 35(11): 82-83.