Huadian Technology ›› 2018, Vol. 40 ›› Issue (1): 59-61.

Previous Articles     Next Articles

Analysis of ultralow emission transformation of a 1000MW coalfired unit

  

  1. 1.Huadian Jiangsu Energy Company Limited Jurong Power Plant, Jurong 212400, China; 2.Huadian Electric Power Research Institute,Hangzhou 310030,China
  • Published:2018-01-25

Abstract:

Taking an ultralow emission transformation project of 2×1000MW coalfired units in Jiangsu as an example, it introduces the denitration, desulfurization technology transformation scheme, demonstrates the feasibility and effectiveness of transformation and the problems should be aware of. The actual data shows that the pollutant indicator after transformation can meet the requirements of ultralow emission.