华电技术 ›› 2011, Vol. 33 ›› Issue (9): 72-76.

• 节能与环保 • 上一篇    下一篇

600MW机组脱硫系统运行优化

聂鹏飞,马磊,张鹏   

  1. 河北大唐国际王滩发电有限责任公司,河北唐山063611
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2011-09-25 发布日期:2011-09-25

Experimental Research on operation optimization of desulphurization system of 600MW unit

NIE Pengfei, MA Lei, ZHANG Peng   

  1. Hebei Datang International Wangtan Power Generation Company Limited, Tangshan 063611, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2011-09-25 Published:2011-09-25

摘要: 介绍了河北大唐国际王滩发电有限责任公司2×600MW机组石灰石-石膏湿法烟气脱硫系统运行优化的经验,给出了运行优化的具体措施。通过试验和统计分析,得出了脱硫系统的较佳运行方式。

关键词: 湿法烟气脱硫, 运行优化, 试验

Abstract: The experiences of operation optimization of limestonegypsum wet FGD system of 2×600MW unit in Hebei Datang International Wangtan Power Generation Company Limited were introduced. The concrete measures of operation optimization were given. Based on experiment and the statistical analysis, the better operation mode of desulphurization system was obtained.

Key words: wet flue gas desulphurization (wet FDG, WFGD), operation optimization, experiment