华电技术 ›› 2012, Vol. 34 ›› Issue (10): 52-54.
• 技术交流 • 上一篇 下一篇
耿卫众1,郝相俊2
收稿日期:
修回日期:
出版日期:
发布日期:
GENG Weizhong1, HAO Xiangjun2
Received:
Revised:
Online:
Published:
摘要:
以山西兴能发电有限责任公司二期2×600MW直接空冷机组为例,分析了凝结水精处理混床运行周期短、制水量少、树脂再生频繁的问题,从混床进水水质、再生剂纯度、
给水加氨量及失效树脂的输送等方面查找原因,提出了相应的改进措施。实践证明,改进效果明显。
关键词: 凝结水, 精处理, 混床, 制水量, 运行周期
Abstract:
Some problems, such as the short operation cycle, the small amount of the prepared water, the frequent regeneration of the resin and others, existed
in the mixed bed for condensed water fine treatment of the 2×600MW direct air cooled unit of the Shanxi Xingneng Power Generation Company Limited project
phase II. The reasons of the problems were found from several aspects, which include the quality of the mixed bed input water, the purity of the regenerating
agent, the amount of the ammonia added into the feed water and the conveying of the exhausted resin. The improvement measures were proposed, and the practice
shows that the effects of the measures are favorable.
Key words: condensed water, fine treatment, mixed bed, amount of prepared water, operation cycle
耿卫众;郝相俊. 凝结水精处理混床运行周期短的原因分析[J]. 华电技术, 2012, 34(10): 52-54.
GENG Weizhong;HAO Xiangjun. Analysis on reason of short operation cycle of mixed bed for condensed water fine treatment[J]. Huadian Technology, 2012, 34(10): 52-54.
0 / / 推荐
导出引用管理器 EndNote|Ris|BibTeX
链接本文: https://www.hdpower.net/CN/
https://www.hdpower.net/CN/Y2012/V34/I10/52