华电技术 ›› 2012, Vol. 34 ›› Issue (3): 38-40.

• 研究与开发 • 上一篇    下一篇

330MW机组EH油压偏低原因分析

马勇,杜文斌,薛志恒   

  1. 西安热工研究院有限公司,陕西西安710032
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2012-03-25 发布日期:2012-03-25

Analysis on reason of lower EH oil pressure of 330MW unit

MA Yong, DU Wenbin, XUE Zhiheng   

  1. Xi’an Thermal Power Research Institute Company Limited, Xi’an 710032, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2012-03-25 Published:2012-03-25

摘要: 某新建国产330MW机组出现EH油压偏低的现象,逐步排除了供油泵出力不足、蓄能器泄漏、油泵出口溢流阀泄漏、再生装置内漏、主汽门和调门内漏以及AST电磁阀关不严等原因,最终找到导致油压偏低的真正原因是超速保护控制(OPC)电磁阀入口细管少装了1个节流孔。

关键词: 火电机组, 亚临界, 高压抗燃油, 电液控制系统, 油压, 节流孔, 电磁阀

Abstract: The EH oil pressure of a new domestic 330MW unit became lower. Some possible reasons, such as the insufficient output of the oil feed pump, the leakage of the energy accumulator, the leakage of the overflow valve in outlet of the oil pump, the internal leakage of the regeneration device, the internal leakage of the main stop valve and the regulating valve and the incomplete close of the AST electromagnetic valve, were excluded one by one. At last, it was found that in the inlet thin tube of the OPC electromagnetic valve, one designed orifice was not installed, and this is the real reason of the lower oil pressure.

Key words: thermal power unit, subcritical, high pressure fire-resistant oil, electro-hydraulic control system, overspeed protection control (OPC), electromagnetic valve