华电技术 ›› 2012, Vol. 34 ›› Issue (5): 63-66.

• 节能与环保 • 上一篇    下一篇

石灰石-石膏法烟气脱硫系统厂用电率的分析与优化

杜振,朱跃,何胜,程雪山,张杨   

  1. 华电电力科学研究院,浙江杭州310030
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2012-05-25 发布日期:2012-05-25

Analysis and optimization of service power consumption rate of limestonegypsum flue gas desulphurization system

DU Zhen, ZHU Yue, HE Sheng, CHENG Xueshan, ZHANG Yang   

  1. Huadian Electric Power Research Institute, Hangzhou 310030, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2012-05-25 Published:2012-05-25

摘要:

分析了机组容量、机组负荷、燃煤硫分对石灰石-石膏法烟气脱硫系统厂用电率的影响,得出脱硫系统厂用电率高的主要原因是燃煤硫分偏高、脱硫系统入口烟尘浓度偏高、

设备堵塞、结垢等。提出了调整脱硫运行方式、加强设备的维护力度、保证仪器仪表的准确性等降低脱硫系统厂用电率的优化措施,为烟气脱硫系统正常、稳定、节能运行打下了

基础。

关键词: 石灰石-石膏法, 烟气脱硫, 厂用电率, 分析, 优化

Abstract:

The influence of the unit capacity, the unit load and the sulfur content in fired coal on the service power consumption rate of the limestone

gypsum FGD system was analyzed; and it was obtained that the main reasons of the higher service power consumption rate of the FGD system are the higher

sulfur content in fired coal, the higher soot concentration in the inlet of FGD system, the equipment blockage, the scaling and others. In order to reduce

the service power consumption rate of the FGD system, some optimization measures, such as to regulate the desulphurization operation mode, to adopt powerful

maintenance measures, to insure the precision of the instruments and so on, were proposed and adopted, which lays a foundation for normal, stable and energysaving operation of the FGD system.

Key words: limestone-gypsum method, flue gas desulphurization, service power consumption rate, analysis, optimization