330MW直接空冷机组无辅助汽源的启动方式

汪潮洋,孙建磊, 南伟亮,王慧   

  1. 河北省电力研究院,河北石家庄050021
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2012-09-25 发布日期:2012-09-25

Start mode of 330MW direct aircooled unit without auxiliary steam source

WANG Chaoyang, SUN Jianlei, NAN Weiliang, WANG Hui   

  1. Hebei Electric Power Research Institute, Shijiazhuang 050021, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2012-09-25 Published:2012-09-25

摘要: 介绍了基建机组或孤岛运行机组在无辅助汽源情况下的快速恢复方法。以常规恢复方法为基准进行了对比分析,采用该方法不仅可减少事故时间,而且可提高机组的经济性。机组在冬季运行工况下,采用该方法对避免空冷系统的结冰可起到重要的作用。

关键词: 无辅助汽源, 热态启动, 直接空冷, 经济性

Abstract: The rapid hot start method of the unit of capital construction and the unit operating in lone island mode without auxiliary steam source was introduced and analyzed. Comparing with the normal hot start method, the new method can shorten the accident time and increase the economical efficiency of the unit. In addition, this method plays an important role for prevention of freezing of direct aircooled system in winter.