华电技术 ›› 2014, Vol. 36 ›› Issue (5): 52-55.

• 技术交流 • 上一篇    下一篇

增压风机增加旁路烟道改造工程

  

  1. (福建华电可门发电有限公司,福州〓350512)
  • 出版日期:2014-05-25 发布日期:2014-07-15

Reformation of adding bypass flue for booster fan

  1. (Fujian Huadian Kemen Power Generation Company Limited, Fuzhou 350512, China)
  • Online:2014-05-25 Published:2014-07-15

摘要: 摘要:福建华电可门发电有限公司 #3机组增压风机加装旁路改造,通过开展增压风机旁路运行相关试验,评估了增压风机加装旁路烟道前后机组运行的经济性,得出增加旁路烟道对节能降耗好和成本回收时间短的结论。

关键词: 关键词:增压风机, 旁路烟道, 经济性, 节能降耗

Abstract: Abstract:In Fujan Huadian Kemen Power Generation Company Limited, a bypass flue was added for the booster fan of unit No.3. The relevant test of booster fan bypass operation was carried out. According to the test result, the unit economical efficiency before and after reformation was evaluated, and the evaluation conclusion is that to add the bypass flue is useful for energy conservation and consumption reduction, and the cost of the reformation can be recovered for a short period.

Key words: Keywords:booster fan, bypass flue, economical efficiency, energy conservation and consumption reduction