摘要: 摘要:某电厂超临界机组循环水泵大轴发生断裂,造成了重大设备事故。对循环水泵大轴断口进行了光谱、硬度和金相检测,依据检测结果,分析了循环水泵大轴发生断裂的原因,提出了预防措施。

关键词: 关键词:循环水泵大轴, 断裂, 检测, 原因分析, 防护措施

Abstract: Abstract:A fracture accident occurred to major shaft of the circulating water pump for the super critical unit in a power plant. The fracture of major shaft for the circulating water pump was inspected, through spectral analysis and metallography were hardness test. According to the test results, the causes of c major shaft fracture of the circulating pump were analyzed, and relative precautionary measures were put forward.

Key words: Keywords:circulating water pump major shaft, fracture, inspection, cause analysis;precautionary measures