华电技术 ›› 2018, Vol. 40 ›› Issue (2): 50-51.

• 技术交流 • 上一篇    下一篇

双级动叶可调轴流引风机卡涩原因分析与改进

  

  1. 1.华电国际技术服务中心,济南〓250014; 2.国网山东省电力公司电力科学研究院,济南〓250003
  • 出版日期:2018-02-25 发布日期:2018-03-28

Reason analysis and improvement on the blades fault of twostage adjustable moving blade axial flow draft fan

  1. 1.Huadian Power International Technical Service Center, Jinan 250014, China; 2.State Grid Shandong Electric Power Research Institute, Jinan 250003, China
  • Online:2018-02-25 Published:2018-03-28

摘要:

通过分析发现,由于设计、检修、运行方式等方面的原因,造成了双级动叶可调轴流引风机动叶频繁卡涩。根据实践,从设计改进、运行维护和检修等方面对预防、处理措施进行了探讨,提出了改进意见,可为同类型引风机卡涩异常处理提供参考。

关键词:

Abstract:

Through analysis, it is found that the twostage moving blade adjustable axial flow fan is frequently jammed because of the design, maintenance, operation mode and so on. According to the practice, the prevention, countermeasures are discussed and the improvement opinion is put forward,considering the design improvement, operation maintenance and overhaul. It can provide a reference for jamming issues of induced draft fan with similar condition.