摘要: 摘要:CS2024型给煤机在运行过程中出现了给煤率异常的问题,直接恶化了燃烧控制系统的性能,限制了机组出力,影响机组运行的安全。对给煤率异常的原因进行了分析,提出了防范措施,取得了较好的效果。

关键词: 关键词:CS2024型称重式给煤机, 给煤率, 处理, 防范措施

Abstract: Abstract:In operation of CS2024 electronic weighing coal feeder, a problem of abnormal coal feeding rate occurred, which deteriorated performance of the combustion control system directly. The output power of the unit was limited, and the unit operation safety was affected. The reasons of abnormal coal feeding rate were analyzed. The preventive measures were proposed, and better result was obtained.