华电技术 ›› 2020, Vol. 42 ›› Issue (11): 39-43.

• 中低温热能利用 • 上一篇    下一篇

基于喷射式换热的水热型地热集中供热系统效益分析

  

  1. 1. 北京建筑大学 北京市建筑能源高效综合利用工程技术研究中心,北京 100044;2. 丹麦技术大学 土木工程 学院,林比市 2800;3. 北京热科能源技术研究有限公司,北京 100083
  • 出版日期:2020-11-25

Benefit analysis of hydrothermal geothermal central heating systems based on ejector heat exchangers

  1. 1.Beijing Engineering Research Center of Sustainable Energy and Buildings,Beijing University of Civil Engineering and Architecture,Beijing 100044,China;2.Department of Civil Engineering,Technical University of Denmark,Lyngby 2800, Denmark;3. Beijing Reke Energy Technology Research Company Limited,Beijing 100083,China
  • Published:2020-11-25

摘要: 为解决常规水热型地热供热模式的经济供热半径短、供热规模较小、水热型地热资源开发利用率低等问 题,分析水热型地热和增效型喷射式换热机组的特点,提出了基于喷射式换热的水热型地热集中供热新模式。从 热力学和经济学等角度对新型集中供热系统和常规供热系统进行比对,结果表明,前者的一次回水温度较低,可大 幅增加一次热网供/回水温差,有利于高效利用水热型地热能和深度回收低温烟气余热。相较于常规燃气锅炉集中 供热系统,新型集中供热系统可提高约 86.0 百分点的化石能源利用效率和约 9.7 百分点的系统产品㶲效率,降低约 70.0% 的天然气消耗量,节约供热成本约 32.47 元/GJ。新型集中供热系统地热经济输送距离可以达到 55.2 km,可 解决水热型地热田与供热负荷中心空间分布的不匹配。

关键词: 集中供热, 水热型地热, 节能减排, 大温差输热, 喷射式换热, 供热负荷

Abstract: To deal with the problems of short economic heating radius,small heating scale and low utilization efficiency of hydrothermal geothermal resources existing in the conventional hydrothermal geothermal heating mode, a new hydrothermal geothermal central heating system based on enhanced ejector heat exchangers is proposed according to the characteristics of both hydrothermal geothermal resources and ejector heat exchangers. The results show that the new heating mode is of a lower primary return water temperature,which facilitates mounting the temperature difference between supply and return water,utilizing hydrothermal geothermal heat and recovering waste heat in flue gas. Comparing with the conventional central heating system based on gas-fired boilers,the new hydrothermal geothermal central heating system can increase the energy efficiency of fossil fuel by about 86.0%,boost the product exergy efficiency(PEE)of the system by about 9.7%,reduce the heating cost by about 32.47 yuan/GJ ,and save natural gas consumption by about 70%.The cost- effective distance of the new hydrothermal geothermal central heating system reaches 55.2 km,which could be used to resolve the space distribution mismatching between the hydrothermal geothermal heat fields and the heating load center.

Key words: district heating, hydrothermal geothermal heat, energy saving and emission reduction, large temperature difference heat transmission, enhanced ejector heat exchanger, heating load