Huadian Technology ›› 2008, Vol. 30 ›› Issue (10): 61-62.
• 一线动态 • Previous Articles Next Articles
SHENG Hu
Received:
Revised:
Published:
Abstract: The hydrogen purity of unit №3 in Huadian Zhangqiu Power Generation Corporation Limited was decreasing faster, and this caused that the hydrogen inside generator must be purified frequently. The problems mentioned above were analyzed, some relevant measures were adopted, and the sealing oil system was adjusted using running and shut-down opportunity. Then the problem of hydrogen purity decrease was resolved finally, and unit safety, stable operation was achieved.
Key words: hydrogen cooled unit, hydrogen purity, purification, sealing oil system, adjustment
SHENG Hu. Research of hydrogen purity decrease in hydrogen cooled unit[J]. Huadian Technology, 2008, 30(10): 61-62.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2008/V30/I10/61
Retrofit and combustion adjustment of a lownitrogen burner in a 330MW cogeneration unit
Cause analysis and preventive measures of abnormal regulation of AGC in a power plant
Clean coal heatsupply and integrated energy utilization
Practice of centralizing and intelligent transformation on heating supply of thermal power enterprises