Huadian Technology ›› 2009, Vol. 31 ›› Issue (10): 27-31.
• 研究与开发 • Previous Articles Next Articles
ZHANG Hongyuan, L Daohua, YAN Ping, L Jizu
Received:
Revised:
Published:
Abstract: The application of bending design for main service piping adopted in 2×1000MW ultrasupercritical units of Shanghai Waigaoqiao Third Power Plant was introduced. The technical advantage of the replacement of elbow by using of bending was analyzed. The comparing of concrete data shows that the adoption of bending design can reduce the investment, decrease the heat consumption rate which is helpful for energy conservation and emission reduction, and the design is beneficial for the piping safe operation simultaneously.
Key words: main service piping, bending, elbow, compare
ZHANG Hongyuan;L Daohua;YAN Ping;L Jizu. The comparative analysis of bending and elbow in main service piping design of coalfired power plant[J]. Huadian Technology, 2009, 31(10): 27-31.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2009/V31/I10/27
Analysis of temperature field and thermal stress of hightemperature steam pipe elbow in startup stage