Huadian Technology ›› 2009, Vol. 31 ›› Issue (10): 76-78.

• 节能与环保 • Previous Articles    

Technology analysis and design optimization of limestonebased wet FGD

TAO Aiping   

  1. China Huadian Engineering Corporation Limited, Beijing 100048, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2009-10-25 Published:2009-10-25

Abstract: Combining with the limestonebased wet FGD system of Guizhou Dafang Power Plant, the difference on system configuration and electricity consumption of different desulphurization technology under the same wet FGD process, same design condition and same performance requirement was expounded, and then the importance of FGD system design optimization was explained.

Key words: limestone-based wet FGD, Marsulex(MET) technology from American, LLB(Bischoff)technology from Germany, electricity consumption