Huadian Technology ›› 2009, Vol. 31 ›› Issue (7): 60-61.
• 技术交流 • Previous Articles Next Articles
TIAN Jianzhou
Received:
Revised:
Published:
Abstract: Taking a 600MW supercritical boiler of Fengtai Power Generation Branch of Huaizhe Coal and Power Corporation Limited as example, the application of the flue gas damper in reheat temperature adjustment was introduced. The control principle of flue gas damper, the practical application and the matters needing attention in application were expounded. The problems caused by flue gas damper were summarized, and some improving measures were given.
Key words: supercritical boiler, flue gas damper, reheat temperature adjustment, practical application, improving measure
TIAN Jianzhou. Application of flue gas damper in reheat temperature adjustment[J]. Huadian Technology, 2009, 31(7): 60-61.