Huadian Technology ›› 2010, Vol. 32 ›› Issue (11): 5-6.
• 专题综述 • Previous Articles Next Articles
WANG Bin1,2, LI Dewen2, ZHAO Yusheng2
Received:
Revised:
Published:
Abstract: After the boiler No.3 of Huadian Weifang Power Generation Corporation Limited project phase II was put into operation, its index of combustible matters in fly ash are always higher. In order to effectively reduce the combustible matter in fly ash and raise unit economical efficiency, some measures, such as to improve the air distribution mode, to ensure the appropriate oxygen content and advisable fineness of pulverized coal, were adopted, and the index of combustible matter in fly ash of unit No.3 was improved obviously.
Key words: combustible matters in fly ash, air distribution mode, oxygen content, fineness of pulverized coal
WANG Bin;;LI Dewen;ZHAO Yusheng. Control and operation adjustment method for combustible matters in fly ash of 670 MW boiler[J]. Huadian Technology, 2010, 32(11): 5-6.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2010/V32/I11/5