Huadian Technology ›› 2010, Vol. 32 ›› Issue (12): 51-53.
• 技术交流 • Previous Articles Next Articles
LIU Tao
Received:
Revised:
Published:
Abstract: The characteristics and technical parameters of induced draft fan of the boiler with bagtype dust remover in a power plant were introduced. Based on this, the reasons of induced draft fan stall were analyzed. The relevant measures were adopted, and favorable effects were obtained.
Key words: induced draft fan, technical parameter, reason of stall, air quantity, wind pressure
LIU Tao. Analysis on reason of induced draft fan stall of 600MW unit and countermeasures[J]. Huadian Technology, 2010, 32(12): 51-53.