Huadian Technology ›› 2010, Vol. 32 ›› Issue (3): 4-6.

• 专题综述 • Previous Articles     Next Articles

Reason analysis of high combustible matter content in flyash of 1025t/h boiler and improvement

GONG Hanqiang, LIU Zhaojun, ZHANG Nailiang, SHI Tianzuo, QU Xiaolin   

  1. Shengli Power Plant, Shengli Petroleum Administration, Sinopec Group, Dongying 257087, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2010-03-25 Published:2010-03-25

Abstract: Due to the asreceived coal grade was reduced and the sundries in raw coal was increased, the directfired system of 1025t/h boiler of Shengli Power Plant was often blocked, and this caused the combustion of boiler to be not stable and the combustible matter in flyash to be increased. The blockage reason of the directfired system was analyzed, and an improvement scheme was determined and implemented. Then, the safety, stable and economical operation of the boiler was ensured.

Key words: coal grade, classifier, blockage, combustible matter in fly-ash