Huadian Technology ›› 2010, Vol. 32 ›› Issue (9): 10-11.
• 专题综述 • Previous Articles Next Articles
ZHONG Shanxia, ZHANG Yuming, SHEN Yuhui
Received:
Revised:
Published:
Abstract: The water balance of limestonegypsum wet flue gas desulphurization system and its absorption tower was calculated according to different design conditions. The affecting factors of water balance in operation process were analyzed, and a reference for operation and management of desulphurization installation was provided.
Key words: limestone-gypsum wet flue gas desulphurization, gas-gas heater (GGH), absorption tower, water balance
ZHONG Shanxia;ZHANG Yuming;SHEN Yuhui. Operation factors affecting water balance of limestonegypsum wet flue gas desulphurization system[J]. Huadian Technology, 2010, 32(9): 10-11.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2010/V32/I9/10
Water balance test and watersaving recommendations for gasfired power plants