Analysis on vacuum problem of condenser of 300MW turboset

PENG Quanyuan, YAN Xianghong   

  1. Mawan Power Generation Company Limited, Shenzhen Energy, Shenzhen 518052, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2011-10-25 Published:2011-10-25

Abstract: The factors influencing on the vacuum of 300MW turboset were analyzed. Combining with the actual situation of the power plant, the vacuum problem occurred in condensing turbine unit was expounded. The method to enhance the condenser vacuum was found out, providing reference for the persons of the same profesional to handling similar problems.