Huadian Technology ›› 2011, Vol. 33 ›› Issue (6): 68-71.

• 节能与环保 • Previous Articles     Next Articles

Fault diagnosis and reformation of absorption tower agitator in 600MW unit FGD system

YIN Pengfei   

  1. Guangdong Zhuhai Jinwan Power Generation Corporation Limited, Zhuhai 519050, China
  • Received:1900-01-01 Revised:1900-01-01 Published:2011-06-25

Abstract: The corrosion and fracture of agitator blade of absorption tower in unit No.3 desulphurization system of Jinwan Power Generation Corporation Limited. were analyzed. Combining with practical situation of the engineering design, the preventive and improvement measures were put forward to ensure safe and stable operation of the desulphurization system.

Key words: absorption tower, agitator, fracture, stress corrosion, improvement measure