Analysis on reason of rapid dropping of condensate pump output power and countermeasures

HONG Li   

  1. Guangdong Yudean Jinghai Power Generation Company Limited, Huilai 515200, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2012-10-25 Published:2012-10-25

Abstract:

The problem of the condensate pump output power rapidly dropping repeatedly ocuurred in the debugging process of the 1000MW unit in Huilai Power

Plant was analyzed. The basic reason of above problem was found,and the practical feasible treatment method and preventive measures were put forward.