Huadian Technology ›› 2012, Vol. 34 ›› Issue (4): 56-57.
• 技术交流 • Previous Articles Next Articles
CHEN Wei, LIN Fei
Received:
Revised:
Published:
Abstract: Since the unit No.1 of Huadian Fujian Shaxian Chengguan Hydropower Company Limited was put into operation, the deexcitation resistor was damaged first time. Aiming at the happened problem, the reason of the fault was analyzed. Using the exclusive method, it was diagnosed that the fault is deexcitation resistor failure preliminarily. After the deexcitation resistor was replaced by new one, the unit operates normally.
Key words: excitation system, deexcitation circuit, rotor over-voltage, damage of deexcitation resistor, reason analysis
CHEN Wei;LIN Fei. Analysis on reason of damage of deexcitation resistor in excitation system[J]. Huadian Technology, 2012, 34(4): 56-57.