Huadian Technology ›› 2012, Vol. 34 ›› Issue (5): 48-51.
• 技术交流 • Previous Articles Next Articles
CAO Yongqi, YAO Zhongdong
Received:
Revised:
Published:
Abstract:
In operation of side A induced draft fan of boiler No.1 in Yaomeng Power Company Limited, the stall phenomenon occurred. According to the operation
data and theory analysis, it was considered that the stall reason of the said induced draft fan is low temperature corrosion caused by ash deposition of the
preheater. After effective measures were adopted, the stall phenomenon was eliminated.
Key words: induced draft fan, stall, low temperature corrosion, ash deposition, responsive measure
CAO Yongqi;YAO Zhongdong. Analysis on reasons of stall of operating induced draft fan and preventive measures[J]. Huadian Technology, 2012, 34(5): 48-51.