Huadian Technology ›› 2012, Vol. 34 ›› Issue (7): 58-59.
• 技术交流 • Previous Articles Next Articles
QIN Xichao, GUO Jie
Received:
Revised:
Published:
Abstract: The reason on overlarge vibration of the bearing No.3 in cold start of unit No.3 in Guangdong Yudean Jinghai Power Generation Company Limited was analyzed, and relevant countermeasures were proposed, which provide reference for similar problem treatment.
Key words: ultra supercritical unit, cold start, vibration, reheater, medium speed warming
QIN Xichao;GUO Jie. Reason analysis and treatment of vibration occurred in cold start process of 1000MW ultra supercritical unit[J]. Huadian Technology, 2012, 34(7): 58-59.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2012/V34/I7/58
Study on the structure design of quadrangle towerframe steel chimney
Influence of 600MW supercritical unit steam distribution characteristics on shaft vibration
Optimization of air preheater leakage control system in 670MW unit
Cause analysis on the fillet weld cracking of the outlet header socket of hightemperature reheater
Analysis and treatment of abnormal vibration of industrial water pump
Analysis and treatment of abnormal vibration of a steam turbine of 600MW unit
Study on the distribution and optimization control of SCR denitration system flue gas flow field