Research on utilization of residual heat in lowtemperature flue gas of coalfired power plant

SHEN Yuhui, TAO Aiping, DENG Huipeng   

  1. China Huadian Engineering Corporation Limited, Beijing 100035, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2012-09-25 Published:2012-09-25

Abstract: Aiming at the problems, which occurred in the desulphurization system of thermal power plant after its GGH was abolished, a solution proposed in this paper is to install a lowtemperature flue gas heat recovery device. The problems existing in present desulphurization systems can be solved including the waste of flue gas heat, the higher water consumption of the wet desulphurization, the unsafe operation of the wet smoke stack after desulphurization and others. In addition, using this solution, the power generation efficiency can be increased by about 0.3% or the lowquality heat equivalent to 4% of generated electricity can be recovered.

Key words: wet desulphurization, energy conservation and emission reduction, merging of boost fan and induced draft fan together, wet smoke stack, flue gas heat recovery