Abstract: Abstract:In operation of the water intake pump of a coalfired power plant, the vibration of the pump exceeded permitted limit. The reasons of the vibration were analyzed, and it was pointed out that the main reasons causing the overoflimit vibration are the external pipeline stress, the insufficient lubricating water pressure and the poor lubricating water quality. The faults were treated, the vibration of the water intake pump weakened, and the water intake pump operates normally.
Key words: Keywords:water intake pump, water intake in riverside, vibration, pipeline stress, lubricating water, reason analysis, treatment
HAN Lizheng. Analysis on reasons of outoflimit vibration of water intake pump[J]. Huadian Technology, 2014, 36(11): 55-57.