Huadian Technology ›› 2014, Vol. 36 ›› Issue (2): 22-26.

Previous Articles     Next Articles

Analysis on debugging technology of direct aircooled unit of power plant

  

  1. (State Nuclear Power Engineering Company, Shanghai 200233, China)
  • Published:2014-02-25

Abstract: Abstract:In debugging and commissioning process of the direct aircooled unit, the problems in design, installation and operation of the unit were exposed gradually. The problems of the aircooled unit, such as the thermal system design, the air cooling island flushing, the aircooled unit starting, the freezeproofing of air cooling island in winter and the influences of strong wind and high temperature, were analyzed. The idea and method to solve the problems were explored actively to ensure safe and stable operation of the direct aircooled unit.

Key words: Keywords:power station, direct aircooled unit, debug, operation analysis, countermeasure