An optimization multiple objective model of distributed coolingheatingpower supply
HUANG Delian
2014, 36(2): 1-3.
Asbtract
(
325
)
Related Articles
|
Metrics
Abstract:The general condition of combined cooling, heating and power(CCHP) system were discussed, for the production process and how the energy transformation was go deep into analyzed. Based on this, individual researches about the correlations between relation operation parameters and several features such as energy utilize rate and demand balance of supply and demand, economy, and need; an multiple objective optimization model was putted, the coordinate and optimization of balance between the three objectives of energy supply and demand balance, economy, and energy utilize rate were achieved.
Application of flue gas condensing technology in gasfired distributed energy system for removing water mist in chimney
HE Binbin, XU Jingjing, LI Heping, SONG Hongtao
2014, 36(2): 4-7.
Asbtract
(
270
)
Related Articles
|
Metrics
Abstract:Taking the Huadian Industry Park Energy Station project as example, the flue gas condensing technology for removing water mist in chimney was discussed. The type selection and arrangement form of the flue gas condensing heat exchanger were analyzed. The economic analysis result shows that the equipment investment can be returned in 6.37 years. Under the condition of stable waste heat users, by using this technology, the problems of deep utilization of flue gas waste heat and chimney visual pollution can be solved.
The application of domestic elastic metal plastic tile in 600MW hydropower units
WANG Guilai, YI Jilin
2014, 36(2): 8-12.
Asbtract
(
285
)
Related Articles
|
Metrics
Abstract:Elastic metalplastics tile of large hydroelectric generating set excel then superior to imported Babbitt alloy sliding bearing in terms of friction power loss, selfadjusting ability, heat resistance, load capacity, pv value and the insulation properties; it has been the good qualities such as large safety margin, high loadcarrying capacity, long useful life and low price. For the purpose of propelling the localization of giant hydraulic turbine and break the foreign countries' monopolization of its key technology, Goupitan Power Plant technicians was based on a lot of researches and innovatively ,have a try at it application elastic metalplastics tile with thrust load capacity as large as 30000kN.After 4 years operation the result make known,when thrust load amount to 30000kN application of domestic elastic metal plastic tile,that hydroelectric unit has feature of operation stability,safety and reliability.
Energy save transformation of closed cooling system of 330MW steam turbine unit in Yangzhou Power Plant
SHI Zhengsheng, YUAN Kaixiang, JI Yayun, JI Jianyu
2014, 36(2): 13-15.
Asbtract
(
330
)
Related Articles
|
Metrics
Abstract:In order to study the water consumption of the closed cooling system for the 330MW unit under different seasons,the operation conditions of closed cooling water system in the whole year 2012 Jiangsu Huadian Yangzhou Power Generation Corporation Limited were analyzed. Based on the features and selection principle of the closed cooling pump, the economy of small pump instead of the original large pump were analyzed . The energy saving plan of adding a small pump in closed cooling water system to reduce the system energy consumption were advanced. Transformation results showed :suitable small pumps can reduce energy consumption of closed cooling water system and the system is running in good condition.
Treatment and case analysis of high power consumption rate in Harbin Third Power Plant
WANG Chuansheng
2014, 36(2): 16-17.
Asbtract
(
389
)
Related Articles
|
Metrics
Abstract:Take #3 unit of Harbin Third Power Plant of Huadian Energy Corporation Limited as an example, the reason of high power consumption rate were analyzed,the influencing factor of power consumption rate were discussed. After take the measures of targeted adjustment and technical transformation, the power consumption rate of #3 unit were clear decreased.
Analysis and calculation of electrical geometric model
LIU Lei
2014, 36(2): 18-21.
Asbtract
(
311
)
Related Articles
|
Metrics
Abstract:The principle and specific calculation method of electrical geometric model were introduced, the exposure distances of all varieties of electrical geometric structure were discussed in categories. Based on this, electrical geometric model was adopted to calculate shielding failure tripout rate of the circuit, and the result was compared with that calculated by order method. According to data derived though the operation, calculations of electrical geometric model are more reliable.
Analysis on debugging technology of direct aircooled unit of power plant
ZHANG Juncheng
2014, 36(2): 22-26.
Asbtract
(
252
)
Related Articles
|
Metrics
Abstract:In debugging and commissioning process of the direct aircooled unit, the problems in design, installation and operation of the unit were exposed gradually. The problems of the aircooled unit, such as the thermal system design, the air cooling island flushing, the aircooled unit starting, the freezeproofing of air cooling island in winter and the influences of strong wind and high temperature, were analyzed. The idea and method to solve the problems were explored actively to ensure safe and stable operation of the direct aircooled unit.
Influence of cutting highpressure heater system off on unit thermal economy performance under variable operating conditions
LEI Tianpeng 1, JIA Jinchan 1, CHAI Guoxu 2
2014, 36(2): 27-29.
Asbtract
(
271
)
Related Articles
|
Metrics
Abstract:Based on the theory of variable operating conditions of steam turbine, the variation of the thermal economy performance indexes of the steam turbine unit after the HP heater had been cut off was analyzed. According to the amplitude of the index variation, the influence of cutting the HP heater off on economic efficiency was estimated. After the HP heater was cut off, the heat rate of the unit increases obviously, the cycle thermal efficiency of the system decreases, and the gross coal consumption rate increases. For more long time the HP heater is stopped, the caused economic loss is more obvious.
Analysis and calculation of kilowatthour data error caused by incorrect voltage loop wiring of kilowatthour meter
HUANG Donglan
2014, 36(2): 30-32.
Asbtract
(
389
)
Related Articles
|
Metrics
Abstract:The measurement principle of kilowatthour meter was introduced. The relation between the true active power and the incorrect meterdisplayed active power caused by incorrect voltage loop wiring of kilowatthour meter was analyzed, and according to this relation, the kilowatthour data error was calculated. Various incorrect voltage loop wiring forms of the kilowatthour meter were analyzed. It was pointed out that the adopted calculation method of the kilowatthour data error must be suitable to the voltage loop wiring form of the kilowatthour meter and practical load condition.
Evaluation of uncertainty of trace iron content in water and steam of power plant detected by graphite furnace atomic absorption method
ZHAO Zhixiang, WU Suozhen, TAI Wenfang
2014, 36(2): 33-35.
Asbtract
(
289
)
Related Articles
|
Metrics
Abstract:The uncertainty of trace iron content in water and steam of power plant detected by graphite furnace atomic absorption method was evaluated. According to the files CNAS-GL06—2066 “Guidance on Evaluating the Uncertainty in Chemical Analysis” and JJF 1135—2005 “Evaluation of Uncertainty in Chemical Analysis Measurement”, the sources of the uncertainty during whole measurement process were analyzed. Each component of the uncertainty was calculated, and the expanded uncertainty on the measurement result was obtained. When the mass fraction of iron in water sample is 3.67μg/L, the expanded uncertainty is 0.16μg/L.In the various uncertainty components, the uncertainty brought by using the regression equation to calculate the iron content has largest influence, so it is necessary to control the related coefficients of the regression equation well. The influence of the digestion and volume calibration process on the uncertainty is very little and can be neglected.
Variable frequency energysaving reformation of water circulating pump in heat supply network of 300MW cogeneration unit
MA Yanxin
2014, 36(2): 36-38.
Asbtract
(
394
)
Related Articles
|
Metrics
Abstract:The composition of the heat supply network system of 300MW cogeneration unit was introduced. The problems happened in operation of water circulating pump in heat supply network were analyzed. A variable frequency energysaving reformation scheme for the water circulating pump in heat supply network was put forward. The total water supply flow of the heat supply network was regulated by the regulating valve installed in outlet of the water circulating pump originally; and in the reformation scheme the total water flow will be regulated by the reformed water circulating pump directly. After the scheme was implemented, the operation and maintenance cost of the unit was decreased; the heat supply safety factor of the heat supply network was increased; the economic benefit and the social effect of the enterprise were enhanced.
Analysis on defects of oil pump for the oil pressure equipment system of Huanglongtan Hydropower Plant and treatment
DENG Chenghong, CAI Xinwu, LI Mingsheng, PENG Jun
2014, 36(2): 39-39.
Asbtract
(
279
)
Related Articles
|
Metrics
Abstract:In the operation of the oil pump No.1 of oil pressure equipment system in the waterturbine generator set No.3 of Huanglongtan Hydropower Plant, the oil pump operated abnormally with large sound, which is serious threat for safe and stable operation of the unit. According to the fault phenomenon, the installation process, the equipment, the skill of the operators and the use of the materials were analyzed, and the oil pump was repaired for eliminating its defects. After the repair, the waterturbine generator set operates safely,the desired result were achieved.
Power flow calculation of power grid based on SSSC
ZHAO Lina
2014, 36(2): 40-43.
Asbtract
(
299
)
Related Articles
|
Metrics
Abstract:Based on the static model of synchronous static series compensator (SSSC), the influence of SSSC on power grid was translated into the equivalent injected power on the nodes. The relation between the node injected power and SSSC control parameters was deduced. According to given power control target, new state equation was established, and a power flow calculation method for power grid containing SSSC under condition of given power control target was proposed. In the calculation process of the method, it is not needed to modify the original grid node admittance matrix. Based on original grid power flow equation, the new state variables were selected, and the influence of SSSC on the power grid was transferred to the amendment of the power flow equation. The effectiveness of the method was verified by practical example.
Optimization of maintenance method for heating surface of boiler stopped as standby for long term
ZHANG Hejing
2014, 36(2): 44-47.
Asbtract
(
301
)
Related Articles
|
Metrics
Abstract:The well maintenance of the inside of boiler, which was stopped as standby for long term, is the basic premise for ensuring safe and economic operation of the boiler. The corrosion is important factor to shorten the service life of the boiler stopped as standby for long term. Taking the boiler optimized maintenance method of Fujian Huadian Shaowu Power Generation Company Limited as example, the reasons and the damages of boiler corrosion were analyzed, and the advantages and the disadvantages of various maintenance methods were analyzed. The analysis results are useful for safe and economic maintenance of the boiler.
Management measures for preventing leakage of heating surface tubes of boiler
LI Peng
2014, 36(2): 48-50.
Asbtract
(
340
)
Related Articles
|
Metrics
Abstract:Aiming at the problems of fracture and leakage of the heating surface tubes of the water wall, the superheater, the reheater and the economizer of the boiler, starting from the view of management, the preventive measures were proposed to prevent the leakage accident of the heating surface tubes of the boiler.
Diagnosis and analysis on abnormal steam extraction parameters of a 600MW supercritical unit
XU Xing, HUANG Qilong, DAI Weibao
2014, 36(2): 51-52.
Asbtract
(
355
)
Related Articles
|
Metrics
Abstract:A 600MW unit operates continuously for two years, and its HP steam extraction parameters deviated from the design value seriously. So the heat consumption rate of the unit increased greatly, which influenced on safe and economic operation of the unit vastly. By means of comparison of the operation data and the performance test results of the unit in different periods, considering the main steam flow, the operation parameters of the heaters and the variation of the pressure ratio of stages, the reasons of the abnormal HP steam extraction parameters were analyzed. The conclusion of the analysis is that there is scale formation in the flow path of the HP cylinder, and it was suggested to open the cylinder for maintenance. The result in this paper can be used as reference for safe operation and maintenance of steam turbine.
Reformation of fanshaped plate gap control system for air preheater
WANG Fangdong, WANG Jie
2014, 36(2): 53-54.
Asbtract
(
282
)
Related Articles
|
Metrics
Abstract:A part of air preheater control equipments of boiler No.5 in Huadian International Zouxian Power Plant was damaged, which caused that the gap control system can not be put into operation normally, the air leakage increased, and the boiler efficiency was affected. The fanshaped plate gap control system was reformed and brought into DCS to realize centralized control. After the reformation, the radial air leakage of the air preheater had been controlled effectively.
The operation tactics of 670MW supercritical oncethrough boiler under AGC (R) pattern
CHEN Wei, SUN Guoyi
2014, 36(2): 55-56.
Asbtract
(
262
)
Related Articles
|
Metrics
Abstract:When the 670MW supercritical unit of Huadian Weifang Power Generation Company Limited operated under AGC(R) pattern, the larger fluctuation of the unit load leaded the unit parameters to be unstable, and the unit had to exit from AGC(R) pattern frequently. Aiming at this problem, the possible reasons were analyzed, and some targeted measures, such as to control intermediate point temperature, to adjust the coal quantity in ignition stage and last stage of load variation and so on, were adopted. So the operational reliability and economic efficiency of large unit under AGC(R) pattern were improved.
Analysis on reason of gradually increasing of acid consumption in positive ion exchanger and treatment
CAO Deping
2014, 36(2): 57-59.
Asbtract
(
367
)
Related Articles
|
Metrics
Abstract:Taking the treatment of high acid consumption incident of Hunan Huadian Changsha Power Generation Company Limited as example, the factors, which may leading to acid consumption increasing, such as the source water quality, the resin quality, the resin quantity, the pollution, the equipment factors, the acid quality, the regeneration parameter control, the water temperature and others, were analyzed term by term. Aiming at different influencing factors, different treatment measures were adopted, and obvious result was obtained.
Variable frequency reformation of primary air fan and optimization of RB function
ZHU Zhijun
2014, 36(2): 60-62.
Asbtract
(
372
)
Related Articles
|
Metrics
Abstract:Taking the newbuilt 300MW unit of a heat and power company in Dandong as example, the defects of the primary air fan, such as high energy consumption and large noise, were analyzed. The thermal control strategy was optimized, and the variable frequency automatic adjustment function was perfected. So the energy consumption and the noise were reduced, and the safety, reliability and the economic efficiency of the unit were improved.
Analysis on reason of suddenly decreasing of oil pressure in lubricating oil system of small turbine in 300MW unit and treatment
ZHENG Xiaohong
2014, 36(2): 63-64.
Asbtract
(
397
)
Related Articles
|
Metrics
Abstract:Taking the Huadian International Shiliquan Power Plant as example, the function of the small turbine lubrication oil system was introduced. The reasons of the incident of the small turbine shutdown caused by suddenly decreasing of the small turbine lubrication oil pressure were analyzed. The small turbine lubrication oil system was reformed, and the hidden trouble of the suddenly decreasing of the small turbine lubrication oil pressure was eliminated.
Analysis on fracture of axial flow fan blade in air cooling island of direct aircooled unit
ZHOU Kai
2014, 36(2): 65-68.
Asbtract
(
313
)
Related Articles
|
Metrics
Abstract:Taking the 600MW direct aircooled unit as example, the reasons of abnormal fracture of axial flow fan blade in air cooling island were analyzed. The measures for preventing blade fracture were proposed, which can be used as reference for similar steam turbine in installation of axial flow fan blade in the air cooling island.
Analysis on reasons causing dissolved oxygen in condensate water of 1000MW unit to exceed standard and control measures
QU Haiying, SUN Lei
2014, 36(2): 69-72.
Asbtract
(
364
)
Related Articles
|
Metrics
Abstract:In practical operation of the 1000MW unit of Huadian International Zhouxian Power Plant, the dissolved oxygen in condensate water exceeded standard. The factors influencing on the dissolved oxygen in the condensate water, such as the condensate water make up model, the return water temperature of feed pump sealing water, the output of the vacuum pump and the mechanical seal of the condensate pump, were analyzed. The comprehensive control measures were put forward, and the safe and economical operation of the unit was ensured.
Application of incentive mechanism through practical management in the wind power enterprise
QI Fang, BAO Jinchun
2014, 36(2): 73-74.
Asbtract
(
272
)
Related Articles
|
Metrics
Abstract:In order to rise the efficiency management and enhance the management mechanism of the enterprise, the theoretical foundation of incentive mechanism from the angle of psychotherapy were expounded.Lay down variable salary system,respecting employees, concerning subordinates, fostering humanbased concept, meeting the needs of employees by involving them into management and achieving their selfworth are effective means of enterprise management were point out. These measures used in wind power enterprise, fine effect of positive motivation were obtained.
Analysis on reasons of high fault rate of wind power generator collecting ring and countermeasures
LI Peng, YAO Junbing, BI Xiaoying
2014, 36(2): 75-77.
Asbtract
(
411
)
Related Articles
|
Metrics
Abstract:Aiming at the too high fault rate of collecting ring of wind power generator in a wind farm, the statistical result of the faults was analyzed, and based on this analysis, it was determined that the main reason of the faults is shortcircuit fault by carbon powder, and to reduce the carbon powder accumulation can reduce the fault rate of shortcircuit caused by carbon powder. It was proposed to add carbon powder cleaning device in the collecting ring chamber. After the measure was implemented, the fault rate reduced from 3.17 times per month to zero.