Huadian Technology ›› 2014, Vol. 36 ›› Issue (2): 53-54.
Previous Articles Next Articles
Published:
Abstract: Abstract:A part of air preheater control equipments of boiler No.5 in Huadian International Zouxian Power Plant was damaged, which caused that the gap control system can not be put into operation normally, the air leakage increased, and the boiler efficiency was affected. The fanshaped plate gap control system was reformed and brought into DCS to realize centralized control. After the reformation, the radial air leakage of the air preheater had been controlled effectively.
Key words: Keywords:air preheater, fanshaped plate, air leakage, gap control, distributed control system (DCS), logic, suggestion
WANG Fangdong, WANG Jie. Reformation of fanshaped plate gap control system for air preheater[J]. Huadian Technology, 2014, 36(2): 53-54.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2014/V36/I2/53
Prediction method for weekly electricity consumption based on LSSVM algorithm
Optimization of air preheater leakage control system in 670MW unit
Transformation methods for PT slowmelting judgment of UN 5000 excitation system