Huadian Technology ›› 2014, Vol. 36 ›› Issue (8): 34-37.
Previous Articles Next Articles
Online:
Published:
Abstract: Abstract:The fault tripping process of the primary air fan moving blade actuator of a 1000MW unit was introduced. The reasons of the accident and the problems encountered in accident treating process were analyzed. The treatment countermeasures under different coordination modes and the primary air fan stall treating method were put forward.
Key words: Keywords:primary air fan, moving blade, stall, coordination
FANG Min. Analysis on reasons of primary air fan fault tripping accident of 1000MW unit and treatment[J]. Huadian Technology, 2014, 36(8): 34-37.
0 / / Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2014/V36/I8/34
Design and application of intelligent algaeblocking equipment for water conveyance main canal
Model selection and installation of coupling for the LM series aeroderivative gas turbine generator