Huadian Technology ›› 2015, Vol. 37 ›› Issue (2): 48-49.

Previous Articles     Next Articles

Analysis on startup fault of butterfly valve oil pump of hydropower station and treatment

  

  1. (1.Zhejiang Huadian Wuxijiang Hydropower Plant, Quzhou 324000, China; 2.Shenzhen CLou Electronics Compang Limited, Shenzhen 518057, China; 3.CAMCE WHU Design & Research Company Limited, Wuhan 430070, China)
  • Online:2015-02-25 Published:2015-04-02

Abstract: Abstract:When the butterfly valve was opened fully, the oil pressure had reduced to oilsupplement position, but the oil pump did not start up normally. Aiming at above fault,the fault was analyzed.Close the butterfly valve and reopening at the shutdown state, make the order of butterfly valve open and pressure maintaining action and self maintenance, the fault is removed.

Key words: Keywords:hydropower plant;butterfly valve, oil pump, startup