Huadian Technology ›› 2015, Vol. 37 ›› Issue (2): 48-49.
Previous Articles Next Articles
Published:
Abstract: Abstract:When the butterfly valve was opened fully, the oil pressure had reduced to oilsupplement position, but the oil pump did not start up normally. Aiming at above fault,the fault was analyzed.Close the butterfly valve and reopening at the shutdown state, make the order of butterfly valve open and pressure maintaining action and self maintenance, the fault is removed.
Key words: Keywords:hydropower plant;butterfly valve, oil pump, startup
LI Jianshan1, LI Lihua2,LI Huabing3. Analysis on startup fault of butterfly valve oil pump of hydropower station and treatment[J]. Huadian Technology, 2015, 37(2): 48-49.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2015/V37/I2/48