Huadian Technology ›› 2015, Vol. 37 ›› Issue (3): 73-75.
Previous Articles
Published:
Abstract: Abstract:Three energysaving reformation schemes of condensate pump, which are to replace the motor, to reduce the stages of vane wheel of the pump and to install the frequency converter, were analyzed and researched. The analysis result shows that to install frequency converter is the best energysaving scheme for the motor. The principle and the technical indexes of the frequency conversion technology were expounded, and the practical effects and the economic benefit of the frequency conversion technology in motor energysaving reformation were described.
Key words: Keywords:energy saving, frequency converter, motor, technical reformation
ZHAO Zhilong. Analysis on condensate pump motor of energy saving reconstruction[J]. Huadian Technology, 2015, 37(3): 73-75.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2015/V37/I3/73
Exploration of permanent magnet speed regulation energysaving technology and its application on 6kV motors