Huadian Technology ›› 2015, Vol. 37 ›› Issue (8): 56-58.
Previous Articles Next Articles
Online:
Published:
Abstract:
Abstract:The type and advantages of the adjacent unitptovided heating system were introduced. The conditions must be satisfied before put into operation and the matters needing attention during put into operation and quit were expounded. Taking the application of adjacent unitprovided heating system of two units of a power plant as example, the economy and security of the adjacent unitprovided heating system used in start process of supercritical oncethrough unit were analyzed, and relevant suggestions were proposed.
Key words: Keywords:supercritical unit, adjacent unitprovided heating, start, hot state wash
NIU Liquan. Application of adjacent unitprovided heating system in supercritical unit[J]. Huadian Technology, 2015, 37(8): 56-58.
0 / / Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2015/V37/I8/56
Cause analysis and solution for ignition failure of V94.3A gas turbine