Huadian Technology ›› 2017, Vol. 39 ›› Issue (1): 27-30.

Previous Articles     Next Articles

FCB operation condition bypass control system improvement

  

  1. China Energy Engineering Group Zhejiang Thermal Power Construction Company Limited, Hangzhou 310016, China
  • Online:2017-01-25 Published:2017-03-23

Abstract:

This paper introduced Indonesia Cilacap 1×660MW ultracritical unit major equipment and bypass control system. Based on the requirement for bypass control system under fast cut back (FCB) operation condition, the bypass control system was improved. After improvement, the unit passed 100% load FCB test. Which can be referred by similar bypass control system design and improvement project. 