Reason analysis and prevention measures of inner wall corrosion of a boiler lowtemperature reheater

  

  1. Shandong Huaneng Laiwu Thermal Power Company Limited, Laiwu 271102, China
  • Published:2017-08-25

Abstract:

For the 330MW subcritical boiler of a certain power plant, two leakage accidents occurred due to the inner wall corrosion of platen reheater and wall type reheater. Combining with the tube cutting inspection on site, sediment test and analysis reports of metallographic and mechanical properties, this paper analyzed the corrosion reason of lowtemperature reheater from the aspects of chemical water treatment, operations of boiler startup and shutdown, etc. After that, it proposed the treatment scheme on site and corresponding anticorrosion measurements.

Key words: